Station initialization
(Station-specific parameter, mark with an “X“ if the function is used.)
Remote initialization |
Cyclic data transmission
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Cyclic data transmission |
Read procedure
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Read procedure |
Spontaneous transmission
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Spontaneous transmission |
Double transmission of information objects with cause of transmission spontaneous
(Station-specific parameter, mark each information type with an “X“ where both a Type ID without time and a corresponding Type ID with time are issued in response to a single spontaneous change of a monitored object.)
The following type identifications may be transmitted in succession caused by a single status change of an information object. The particular information object addresses for which double transmission is enabled are defined in a project-specific list.
Double-point information M_DP_NA_1, M_DP_TA_1 and M_DP_TB_1 |
|
Step position information M_ST_NA_1, M_ST_TA_1 and M_ST_TB_1 |
|
Bitstring of 32 bit M_BO_NA_1, M_BO_TA_1 and M_BO_TB_1 (if defined for a specific project) |
|
Measured value, normalized value M_ME_NA_1, M_ME_TA_1, M_ME_ND_1 and M_ME_TD_1 |
|
Measured value, scaled value M_ME_NB_1, M_ME_TB_1 and M_ME_TE_1 |
|
Measured value, short floating point number M_ME_NC_1, M_ME_TC_1 and M_ME_TF_1 |
Station interrogation
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
global |
|||||
group 1 |
group 7 |
group 13 |
|||
group 2 |
group 8 |
group 14 |
|||
group 3 |
group 9 |
group 15 |
|||
group 4 |
group 10 |
group 16 |
|||
group 5 |
group 11 |
||||
group 6 |
group 12 |
||||
Information object addresses assigned to each group must be shown in a separate table. |
Clock synchronization
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Clock synchronization |
|
Day of week used |
|
RES1, GEN (time tag substituted/ not substituted) used |
|
SU-bit (summertime) used |
Command transmission
(Object-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Direct command transmission |
|
Direct set point command transmission |
|
Select and execute command |
|
Select and execute set point command |
|
C_SE ACTTERM used |
|
No additional definition |
|
Short-pulse duration (duration determined by a system parameter in the outstation) |
|
Long-pulse duration (duration determined by a system parameter in the outstation) |
|
Persistent output |
Transmission of integrated totals
(Station- or object-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Mode A: Local freeze with spontaneous transmission |
|
Mode B: Local freeze with counter interrogation |
|
Mode C: Freeze and transmit by counter-interrogation commands |
|
Mode D: Freeze by counter-interrogation command, frozen values reported |
|
Counter read |
|
Counter freeze without reset |
|
Counter reset |
|
General request counter |
|
Request counter group 1 |
|
Request counter group 2 |
|
Request counter group 3 |
|
Request counter group 4 |
Parameter loading
(Object-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Threshold value |
|
Smoothing factor |
|
Low limit for transmission of measured values |
|
High limit for transmission of measured values |
Parameter activation
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Act/deact of persistent cyclic or periodic transmission of the addressed object |
Test procedure
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Test procedure |
File transfer
(Station-specific parameter, mark with an “X“ if the function is used.)
File transfer in monitor direction
Transparent file |
|
Transmission of disturbance data of protection equipment |
|
Transmission of sequences of events |
|
Transmission of sequences of recorded analogue values |
File transfer in control direction
Transparent file |
Background scan
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Background scan |
(Station-specific parameter, mark with an “X“ if the function is only used in the standard direction, “R“ if only used in the reverse direction, and “B“ if used in both directions.)
Acquisition of transmission delay |