615 series DNP3 Point List Manual - Arc protection - Merging unit - Motor protection - Transformer protection - 2 winding - Feeder protection - Voltage regulation - Capacitor bank protection - Interconnection protection - Busbar differential protection (high impedance) - Generator protection - Power management/Load shedding - Back-up protection - DNP3 Communication Manual - DNP3 Point List Manual - 615 series Relion Protection and Control - Relion Protection and Control - 5.0 FP1 IEC - IEC - 22.05.2023 - 615 series
615 Series DNP3 Point List Manual
Copyright
Disclaimer
Conformity
Introduction
This manual
Intended audience
Product documentation
Product documentation set
Document revision history
Related documentation
Symbols and conventions
Symbols
Document conventions
Functions, codes and symbols
DNP3 data mappings
Overview
Supported functions
Supported functions in RED615
Supported functions in REF615
Supported functions in REG615
Supported functions in REM615
Supported functions in RET615
Supported functions in REU615
Supported functions in REV615
Binary inputs
System functions
CTRL.LLN0 Local/remote state (also present in DNP IIN-bits)
LD0.GNRLLTMS1 Time synchronization (1)
LD0.GSELPRT1 Goose supervision (1)
LD0.LDEV1 System values (1)
LD0.LEDGGIO1 Indication LED states OFF/ColorX
LD0.LEDGGIO1 Indication LED states Color1/Color2
LD0.PCSITPC1 Protection communication supervision (1)
LD0.RCHLCCH1 Redundant Ethernet supervision (1)
LD0.SCHLCCHx Ethernet channel supervision (1...3)
Switchgear functions
CTRL.CBXCBR1 Circuit-breaker control (1)
CTRL.DCXSWI1 Disconnector control (1)
CTRL.DCXSWI2 Disconnector control (2)
CTRL.ESXSWI1 Earthing switch control (1)
Sensors and monitoring functions
LD0.ARCSARC1 Arc protection (1)
LD0.ARCSARC2 Arc protection (2)
LD0.ARCSARC3 Arc protection (3)
LD0.BSTGGIO1 Binary signal transfer (1)
LD0.HZCCASPVC1 Current transformer supervision for high-impedance protection scheme for phase A (1)
LD0.HZCCBSPVC1 Current transformer supervision for high-impedance protection scheme for phase B (1)
LD0.HZCCCSPVC1 Current transformer supervision for high-impedance protection scheme for phase C (1)
LD0.IL1TCTR1 Three-phase CT supervision (1)
LD0.IL1TCTR2 Three-phase CT supervision (2)
LD0.MDSOPT1 Runtime counter for machines and devices (1)
LD0.MDSOPT2 Runtime counter for machines and devices (2)
LD0.RESTCTR1 Io CT supervision (1)
LD0.RESTCTR2 Io CT supervision (2)
LD0.RESTVTR1 Uo VT supervision (1)
LD0.RESTVTR2 Uo VT supervision (2)
LD0.SSCBR1 Circuit-breaker condition monitoring (1)
LD0.TCSSCBR1 Trip circuit supervision (1)
LD0.TCSSCBR2 Trip circuit supervision (2)
LD0.UL1TVTR1 Three-phase VT supervision (1)
LD0.UL1TVTR2 Three-phase VT supervision (2)
LD0.XARGGI0130 Alarm/warning
LD0.XRGGIO130 Alarm/warning
Automatic control functions
LD0.OLATCC1 Tap changer control with voltage regulator (1)
Metering and measurand functions
LD0.CMMXU1 Three-phase current measurement (1)
LD0.CMMXU2 Three-phase current measurement (2)
LD0.RESCMMXU1 Residual current measurement (1)
LD0.RESCMMXU2 Residual current measurement (2)
LD0.RESVMMXU1 Residual voltage measurement (1)
LD0.RESVMMXU2 Residual voltage measurement (2)
LD0.VMMXU1 Three-phase voltage measurement (1)
LD0.VMMXU2 Three-phase voltage measurement (2)
Power quality functions
LD0.CMHAI1 Current total demand distortion (1)
LD0.CMHAI2 Current total demand distortion (2)
LD0.PHQVVR1 Voltage variation (1)
LD0.VMHAI1 Voltage total harmonic distortion (1)
LD0.VMHAI2 Voltage total harmonic distortion (2)
LD0.VSQVUB1 Voltage unbalance (1)
Protection functions
LD0.CBPSOF1 Switch onto fault (1)
LD0.COLxPTOC1/CULPTOC1 Capacitor bank overload protection (1)
LD0.CUBxPTOC1 Capacitor bank unbalance current, double Y bridge (1)
LD0.DEFHPDEF1 Directional earth-fault protection, high stage (1)
LD0.DEFLPDEF1 Directional earth-fault protection, low stage (1)
LD0.DEFLPDEF2 Directional earth-fault protection, low stage (2)
LD0.DOPPDPR1 Reverse power/directional overpower protection (1)
LD0.DOPPDPR2 Reverse power/directional overpower protection (2)
LD0.DOPPDPR3 Reverse power/directional overpower protection (3)
LD0.DPHHPDOC1 Three-phase directional overcurrent protection, high stage (1)
LD0.DPHLPDOC1 Three-phase directional overcurrent protection, low stage (1)
LD0.DPHLPDOC2 Three-phase directional overcurrent protection, low stage (2)
LD0.DQPTUV1 Directional reactive power undervoltage protection (1)
LD0.DUPPDPR1 Underpower protection (1)
LD0.DUPPDPR2 Underpower protection (2) – 32U-2
LD0.EFHPTOC1 Non-directional earth-fault protection, high stage (1)
LD0.EFHPTOC2 Non-directional earth-fault protection, high stage (2)
LD0.EFIPTOC1 Non-directional earth-fault protection, instantaneous stage (1)
LD0.EFLPTOC1 Non-directional earth-fault protection, low stage (1)
LD0.EFLPTOC2 Non-directional earth-fault protection, low stage (2)
LD0.EFPADM1 Admittance-based earth-fault protection (1)
LD0.EFPADM2 Admittance-based earth-fault protection (2)
LD0.EFPADM3 Admittance-based earth-fault protection (3)
LD0.FRPFRQ1 Frequency protection (1)
LD0.FRPFRQ2 Frequency protection (2)
LD0.FRPFRQ3 Frequency protection (3)
LD0.FRPFRQ4 Frequency protection (4)
LD0.FRPFRQ5 Frequency protection (5)
LD0.FRPFRQ6 Frequency protection (6)
LD0.H3EFPSEF1 Third harmonic-based stator earth-fault protection (1)
LD0.HAEFPTOC1 Harmonics-based earth-fault protection (1)
LD0.HCUBxPTOC1 Capacitor bank unbalance current, H bridge (1)
LD0.HIAPDIF1 High-impedance differential protection for phase A (1)
LD0.HIBPDIF1 High-impedance differential protection for phase B (1)
LD0.HICPDIF1 High-impedance differential protection for phase C (1)
LD0.HREFPDIF1 High-impedance based restricted earth-fault protection (1)
LD0.HREFPDIF2 High-impedance based restricted earth-fault protection (2)
LD0.INRPHAR1 Three-phase inrush detector (1)
LD0.INTRPTEF1 Transient/intermittent earth-fault protection (1)
LD0.JAMPTOC1 Motor load jam protection (1)
LD0.LEDPTRC1 Global protection signals (1)
LD0.LNPLDF1 Line differential protection with in-zone power transformer (1)
LD0.LOFLPTUC1 Loss of load supervision (1)
LD0.LREFPNDF1 Numerically stabilized low-impedance restricted earth-fault protection (1)
LD0.LSHDPFRQ1 Load-shedding and restoration (1)
LD0.LSHDPFRQ2 Load-shedding and restoration (2)
LD0.LSHDPFRQ3 Load-shedding and restoration (3)
LD0.LSHDPFRQ4 Load-shedding and restoration (4)
LD0.LSHDPFRQ5 Load-shedding and restoration (5)
LD0.LVRTPTUV1 Low-voltage ride-through protection (1)
LD0.LVRTPTUV2 Low-voltage ride-through protection (2)
LD0.LVRTPTUV3 Low voltage ride through protection (3)
LD0.MFADPSDE1 Multifrequency admittance-based earth-fault protection (1)
LD0.MNSPTOC1 Negative-sequence overcurrent protection for machines (1)
LD0.MNSPTOC2 Negative-sequence overcurrent protection for machines (2)
LD0.MPDIF1 Stabilized and instantaneous differential protection for machines (1)
LD0.MPTTR1 Thermal overload protection for motors (1)
LD0.NSPTOC1 Negative-sequence overcurrent protection (1)
LD0.NSPTOC2 Negative-sequence overcurrent protection (2)
LD0.NSPTOV1 Negative-sequence overvoltage protection (1)
LD0.NSPTOV2 Negative-sequence overvoltage protection (2)
LD0.OEPVPH1 Overexcitation protection (1)
LD0.PDNSPTOC1 Phase discontinuity protection (1)
LD0.PHHPTOC1 Three-phase non-directional overcurrent protection, high stage (1)
LD0.PHHPTOC2 Three-phase non-directional overcurrent protection, high stage (2)
LD0.PHIPTOC1 Three-phase non-directional overcurrent protection, instantaneous stage (1)
LD0.PHIPTOC2 Three-phase non-directional overcurrent protection, instantaneous stage (2)
LD0.PHIZ1 High-impedance fault detection (1)
LD0.PHLPTOC1 Three-phase non-directional overcurrent protection, low stage (1)
LD0.PHLPTOC2 Three-phase non-directional overcurrent protection, low stage (2)
LD0.PHPTOV1 Three-phase overvoltage protection (1)
LD0.PHPTOV2 Three-phase overvoltage protection (2)
LD0.PHPTOV3 Three-phase overvoltage protection (3)
LD0.PHPTUV1 Three-phase undervoltage protection (1)
LD0.PHPTUV2 Three-phase undervoltage protection (2)
LD0.PHPTUV3 Three-phase undervoltage protection (3)
LD0.PHPVOC1 Three-phase voltage-dependent overcurrent protection (1)
LD0.PREVPTOC1 Phase reversal protection (1)
LD0.PSPTUV1 Positive-sequence undervoltage protection (1)
LD0.PSPTUV2 Positive-sequence undervoltage protection (2)
LD0.ROVPTOV1 Residual overvoltage protection (1)
LD0.ROVPTOV2 Residual overvoltage protection (2)
LD0.ROVPTOV3 Residual overvoltage protection (3)
LD0.SRCPTOC1 Capacitor resonance protection (1)
LD0.STTPMSU1 Motor start-up supervision (1)
LD0.T1PTTR1 Three-phase thermal protection for feeders, cables and distribution transformers (1)
LD0.T2PTTR1 Three-phase thermal overload protection, two time constants (1)
LD0.TR2PTDF1 Stabilized and instantaneous differential protection for two-winding transformers (1)
LD0.TRPPTRC1 Master trip (1)
LD0.TRPPTRC2 Master trip (2)
LD0.TRPPTRC3 Master trip (3)
LD0.TRPPTRC4 Master trip (4)
LD0.TRPPTRC5 Master trip (5)
LD0.TRPPTRC6 Master trip (6)
LD0.UEXPDIS1 Three-phase underexcitation protection (1)
LD0.UZPDIS1 Three-phase underimpedance protection (1)
LD0.VVSPPAM1 Voltage vector shift protection (1)
LD0.WPWDE1 Wattmetric-based earth-fault protection (1)
LD0.WPWDE2 Wattmetric-based earth-fault protection (2)
LD0.WPWDE3 Wattmetric-based earth-fault protection (3)
Protection-related functions
DR.RDRE1 Disturbance recorder (1)
LD0.CCSPVC1 Current circuit supervision (1)
LD0.DARREC1 Autoreclosing (1)
LD0.LDPRLRC1 Load profile record (1)
LD0.OOSRPSB1 Out-of-step protection (1)
LD0.SCEFRFLO1 Fault locator (1)
LD0.SECRSYN1 Synchronism and energizing check (1)
LD0.SEQSPVC1 Fuse failure supervision (1)
Generic functions
LD0.ESMGAPC1 Emergency start-up (1)
LD0.MAPGAPC1 Multipurpose protection (1)
LD0.MAPGAPC2 Multipurpose protection (2)
LD0.MAPGAPC3 Multipurpose protection (3)
LD0.MAPGAPC4 Multipurpose protection (4)
LD0.MAPGAPC5 Multipurpose protection (5)
LD0.MAPGAPC6 Multipurpose protection (6)
LD0.MAPGAPC7 Multipurpose protection (7)
LD0.MAPGAPC8 Multipurpose protection (8)
LD0.MAPGAPC9 Multipurpose protection (9)
LD0.MAPGAPC10 Multipurpose protection (10)
LD0.MAPGAPC11 Multipurpose protection (11)
LD0.MAPGAPC12 Multipurpose protection (12)
LD0.MAPGAPC13 Multipurpose protection (13)
LD0.MAPGAPC14 Multipurpose protection (14)
LD0.MAPGAPC15 Multipurpose protection (15)
LD0.MAPGAPC16 Multipurpose protection (16)
LD0.MAPGAPC17 Multipurpose protection (17)
LD0.MAPGAPC18 Multipurpose protection (18)
LD0.MVGAPC1 Move (8 pcs) (1)
LD0.MVGAPC2 Move (8 pcs) (2)
LD0.SPCGAPC1 Generic control point (16 pcs) (1)
LD0.SPCGAPC2 Generic control point (16 pcs) (2)
Physical and raw I/O data
LD0.BSTGGIO1 Binary signal transfer (1)
LD0.XAGGIO130 Physical I/O
LD0.XBGGIO110 Physical I/O
LD0.XGGIO100 Physical I/O
LD0.XGGIO110 Physical I/O
LD0.XGGIO120 Physical I/O
LD0.XGGIO130 Physical I/O
Binary outputs
System functions
LD0.LLN0/LDEV1 Reset indications and LEDs, reset device (1)
Switchgear functions
CTRL.CBXCBR1 Circuit-breaker control (1)
CTRL.DCXSWI1 Disconnector control (1)
CTRL.DCXSWI2 Disconnector control (2)
CTRL.ESXSWI1 Earthing switch control (1)
Sensors and monitoring functions
LD0.SSCBR1 Circuit-breaker condition monitoring (1)
Metering and measurand functions
LD0.CMMXU1 Three-phase current measurement (1)
LD0.CMMXU2 Three-phase current measurement (2)
LD0.FLTRFRC1 Fault record (1)
LD0.PEMMTR1 Reset accumulated energy values (1)
LD0.PEMMXU1 Three-phase power and energy measurement (1)
LD0.RESCMMXU1 Residual current measurement (1)
LD0.RESCMMXU2 Residual current measurement (2)
LD0.RESVMMXU1 Residual voltage measurement (1)
LD0.RESVMMXU2 Residual voltage measurement (2)
Power quality functions
LD0.CMHAI1 Current total demand distortion (1)
LD0.PHQVVR1 Voltage variation (1)
LD0.VMHAI1 Voltage total harmonic distortion (1)
Protection functions
LD0.LSHDPFRQ1 Load-shedding and restoration (1)
LD0.LSHDPFRQ2 Load-shedding and restoration (2)
LD0.LSHDPFRQ3 Load-shedding and restoration (3)
LD0.LSHDPFRQ4 Load-shedding and restoration (4)
LD0.LSHDPFRQ5 Load-shedding and restoration (5)
Protection-related functions
DR.RDRE1 Disturbance recorder (1)
LD0.DARREC1 Autoreclosing (1)
LD0.LDPRLRC1 Load profile record (1)
Generic functions
LD0.BSTGGIO1 Binary signal transfer (1)
LD0.SPCGAPC1 Generic control point (16 pcs) (1)
LD0.SPCGAPC2 Generic control point (16 pcs) (2)
LD0.SRGAPC1 Set-reset (8 pcs) (1)
LD0.SRGAPC2 Set-reset (8 pcs) (2)
LD0.SRGAPC3 Set-reset (8 pcs) (3)
LD0.SRGAPC4 Set-reset (8 pcs) (4)
Analog inputs
System functions
CTRL.LLN0 Local/remote/station/off and combinations
LD0.GNRLLTMS1 Time synchronization (1)
LD0.LEDGGIO1 LHMI LED indications, 3 states (1)
LD0.LLN0 Active parameter setting group
LD0.LLN0/LPHD1/LDEV1 System values (1)
Switchgear functions
CTRL.CBXCBR1 Circuit-breaker control (1)
CTRL.DCSXSWI1 Disconnector position indication (1)
CTRL.DCSXSWI2 Disconnector position indication (2)
CTRL.DCSXSWI3 Disconnector position indication (3)
CTRL.DCXSWI1 Disconnector control (1)
CTRL.DCXSWI2 Disconnector control (2)
CTRL.ESSXSWI1 Earthing switch indication (1)
CTRL.ESSXSWI2 Earthing switch indication (2)
CTRL.ESXSWI1 Earthing switch control (1)
Sensors and monitoring functions
LD0.ARCSARC11 Arc protection (1)
LD0.ARCSARC21 Arc protection (2)
LD0.ARCSARC31 Arc protection (3)
LD0.MDSOPT1 Runtime counter for machines and devices (1)
LD0.MDSOPT2 Runtime counter for machines and devices (2)
LD0.SSCBR1 Circuit-breaker condition monitoring (1)
LD0.TPOSYLTC1 Tap changer position indication (1)
Automatic control functions
LD0.OLATCC1 Tap changer control with voltage regulator (1)
Metering and measurand functions
LD0.CMMXU1 Three-phase current measurement (1)
LD0.CMMXU2 Three-phase current measurement (2)
LD0.CSMSQI1 Sequence current measurement (1)
LD0.FLTRFRC1 Fault record (1)
LD0.FMMXU1 Frequency measurement (1)
LD0.HAEFPTOC1 Current harmonics (1)
LD0.PEMMXU1 Three-phase power and energy measurement (1)
LD0.RESCMMXU1 Residual current measurement (1)
LD0.RESCMMXU2 Residual current measurement (2)
LD0.RESVMMXU1 Residual voltage measurement (1)
LD0.RESVMMXU2 Residual voltage measurement (2)
LD0.VMMXU1 Three-phase voltage measurement (1)
LD0.VMMXU2 Three-phase voltage measurement (2)
LD0.VSMSQI1 Sequence voltage measurement (1)
Power quality functions
LD0.CMHAI1 Current total demand distortion (1)
LD0.PHQVVR1 Voltage variation (1)
LD0.VMHAI1 Voltage total harmonic distortion (1)
Protection functions
LD0.LNPDEF1 Line differential protection (1)
LD0.MPTTR1 Thermal overload protection for motors (1)
LD0.PHIZ1 High-impedance fault detection (1)
LD0.T1PTTR1 Three-phase thermal protection for feeders, cables and distribution transformers (1)
LD0.T2PTTR1 Three-phase thermal overload protection, two time constants (1)
Protection-related functions
DR.RDRE1 Disturbance recorder (1)
LD0.DARREC1 Autoreclosing (1)
LD0.SCEFRFLO1 Fault locator (1)
LD0.SECRSYN1 Synchronism and energizing check (1)
Generic functions
LD0.MVI4GAPC1 Integer value move (1)
LD0.SCA4GAPC1 Analog value scaling (1)
LD0.SCA4GAPC2 Analog value scaling (2)
LD0.SCA4GAPC3 Analog value scaling (3)
LD0.SCA4GAPC4 Analog value scaling (4)
LD0.XARGGIO130 RTD inputs
LD0.XRGGIO130 RTD inputs
Double-bit binary inputs
Switchgear functions
CTRL.CBXCBR1 Circuit-breaker control (1)
CTRL.DCXSWI1 Disconnector control (1)
CTRL.DCXSWI2 Disconnector control (2)
CTRL.DCSXSWI1 Disconnector position indication (1)
CTRL.DCSXSWI2 Disconnector position indication (2)
CTRL.DCSXSWI3 Disconnector position indication (3)
CTRL.ESXSWI1 Earthing switch control (1)
CTRL.ESSXSWI1 Earthing switch indication (1)
CTRL.ESSXSWI2 Earthing switch indication (2)
Counters
Metering and measurand functions
LD0.PEMMXU1 Three-phase power and energy measurement (1)
Generic functions
LD0.MVI4GAPC1 Integer value move (1)
Analog ouputs
System functions
LD0.LLN0 Active setting group
Automatic control functions
LD0.OLATCC1 Tap changer control with voltage regulator (1)
Metering and measurand functions
LD0.FLTRFRC1 Fault record (1)
DNP3 protocol implementation
DNP3 device profile
DNP3 implementation table
Glossary